IR1
        Infrared Digital Thermometer with Targeting Laser, 10:1
- Infrared Thermometer has an optical resolution (distance-to-spot) of 10:1
- Features include targeting laser; automatic hold; backlit display; low battery, auto power-off
- Drop protection to 6.6-Foot (2 m)
- Measurement range is -4 to 752-Degree Fahrenheit (-20 to 400-Degree Celsius)
- Not a medical device; thermometer is NOT intended for use on people or animals
- Fixed emissivity at 0.95
- Includes custom pouch and a 9V battery
- Auto Power-Off conserves and extends battery life
- Certified to IEC EN 61326-1.2006, EN608251.1994+A2.2001+A1.2002
7MÊÓÆµ IR1 is an infrared thermometer with a targeting laser. It has a wide measurement range of -4 to 752-Degree Fahrenheit (-20 to 400-Degree Celsius) and a 10:1 distance-to-spot ratio. The backlit display provides clear readings.
Specifications
Type:
          Infrared Thermometer with Targeting Laser
        Application:
          Accurate Targeting and Temperature Measurement
        Special Features:
          Target Laser
        Material:
          Plastic Housing, Electronic Components
        Batteries:
          1 x 9V
        Distance to Spot:
          10:1
        Accuracy:
          Above freezing: ±4° F or ±2%;  Accuracy Below Freezing: ±4° F Plus 0.2 Degrees Per Degree Below 32° F
        Display:
          Digital Backlit
        Display Resolution:
          0.1F (0.1 C)
        Response Time:
          < 0.25s
        Degree Format:
          F or C
        Range:
          -4° to 752° F (-20° to 400° C)
        Standard:
          EN 61326-1:2013, EN 608251:2014, 21 CFR 1040.10 and 1040.11, Class II Laser, CE
        Drop Protection:
          6.6 ft (2 m)
        Included:
          Thermometer; Custom Pouch; 1 x 9V  Battery
        Overall Length:
          6.01''  (15.3 cm)
        Overall Width:
          1.24''  (3.1 cm)
        Overall Height:
          4.14''  (10.5 cm)
        Weight:
          7.1 oz (201 g)
        UPC:
          092644692925
        Warnings
- Read, understand and follow all instructions, cautions and warnings attached to and/or packed with all test and measurement devices before each use.
- LASER RADIATION, Class II laser. Do NOT stare into beam. Exposing eyes to laser radiation can result in severe and permanent eye injuries.
- NEVER look directly into the laser beam emitted by this instrument.
- Usage of this tester in any way other than that specified by the manufacturer can impair safe operation, resulting in severe injury or death.
- Thermometer is NOT intended for use on people or animals.